Showing posts with label Chemical Manufacturers. Show all posts
Showing posts with label Chemical Manufacturers. Show all posts

Saturday, March 21, 2009

Arch Plaster Study





I do a lot of reading. The older I get – and the less time I spend in the field – the more I read all the things that I used to tell myself I would get around to reading when I wasn’t too busy cleaning pools.

And, man, oh man, am I disappointed. For most of my career I’ve just had my head down, focusing on taking care of my pools, going to the odd show here or there, attending a water chemistry seminar now and then. But most of my experience and knowledge was gained poolside. I haven’t paid a lot of attention to what The Experts write – with the exception of Bob Lowry of Lowry Consulting Group. I’ve said it elsewhere in this blog; if you passed the IPSSA water chemistry exam in the last 20 or 25 years, you probably used Mr. Lowry’s books to study for it. He writes great, layman’s explanations of what’s happening in pool and spa water. But other than his stuff and what I’ve picked up on my own from textbooks and the like, I haven’t paid a lot of attention to many of the documents that end up, through their influence, controlling the direction of our industry.

They’re not really documents, per se. You seldom, if ever, see the actual study information – like the real research data, for instance. The internet is huge and space on it is free, or next to free. But still, you never get a look at how tests were really done, or all the data that was collected. Mostly they’re just reports, or, more correctly, brochures. And the ones that seem to have the most stacked decks and the most biased information are the ones from companies selling stuff to us.

Imagine that.

Now, if you’re a homeowner wondering what any of this has to do with how salt damaged your pool, it doesn’t. Use the Labels on the right to find blog pieces about your symptoms or about Making Salt Work for your pool, because this blog piece is going to have a huge water chemistry geek factor. But if you’re one of the guys who is in that spot that I was in until about a year ago, busy with your route and your repairs, with your head down and hardly any time to read what it is everybody says are the latest governing documents for how we ought to take care of our pools, take a minute and read this:

There’s this report that’s been rattling around the internet and the trade shows and seminars for the last several years. You can find it here:

Sorry. Dead Link

or here:

http://piscines-apollo.com/docs/arch_plaster_study.pdf

It’s title on that first website is:

High Cyanuric Acid Levels & Plaster Degradation In Swimming Pools

by Ellen M. Meyer, Ph.D

It’s commonly referred to as the Arch Study. It was a three part study; the first part 5 weeks long, the second part 6 months long, and the third part 4 months long. The gist of the first part of the study is that they put some freshly made plaster coupons into some test tanks and then added as much as 500 ppm cyanuric acid to them, and that over a period of 5 weeks, the cyanuric acid level fell from 500 ppm to about 140 ppm in one tank, and from 200 ppm to about 100 ppm in another tank, and that in both tanks, the cyanuric acid collected as a residue on the surface of the plaster. The fourth paragraph says, “surface analysis showed the accumulation of cyanuric acid on the plaster”.

Okay, so just stop. Stop right there and think for a minute. We’ve all seen pools with 200 ppm stabilizer, right? If you’re honest with yourself, unless you’re Super Poolman, you probably have a handful of pools like that on service right now. I know I do. Most of my pools are under 100. But there are some that are higher. I admit it.

Now, ask yourself a simple question; have you ever seen the cyanuric acid level in those pools drop to as low as 100 ppm and deposit as a residue on the plaster in a 5 week period?

I didn’t think so. In fact, I know so. In fact, it is safe to say – through thirty years of empirical observation - this has never happened anywhere outside the laboratories of Arch Chemicals.

So, how much stabilizer is 500 ppm? Well, it’s about 42 lbs. of stabilizer dissolved into your average 20,000 gallon pool. I’m talking pure, granular stabilizer melted into a freshly plastered backyard pool. Because that’s how this study was done. They took freshly troweled plaster coupons and put them in a tank and put in an amount equal to you putting 42 lbs of stabilizer on Day One of start-up. And how do I know that? Because I finally sat down and gave it several careful readings – something I don’t think many of us have done – and down in the 5th paragraph, in talking about pH control during the 6 month study, they say “because the plaster coupons were new, the pH rose continuously…”

Oh, yeah, that’s Real World. Throwing 42 lbs. of stabilizer into a freshly plastered pool.

So, the assumption I make about that first 5 week test was that they put these new plaster coupons into tanks and didn’t adjust the pH during the 5 week test, and viola! The pH skyrockets and the cyanuric acid falls out of solution, accumulating on the surface of the plaster. Here’s a quote from Dr. Meyer in a Pool & Spa News article: “The cyanuric acid was no longer in solution… It was on the plaster surface, having some kind of affect.”

http://www.poolspanews.com/2008/052/052acid.html

Now, that’s not really a scathing indictment, is it? Having some kind of affect?

I promise you, if you plastered and filled a 20,000 gallon pool, and on Day One you dissolved 42 lbs. of cyanuric acid into the water, then went away for 5 weeks, when you come back, it would be a logical result to have more than half your cyanuric acid plated out on that pool’s surface.

But then, if you didn’t have any pH control for 5 weeks, you’d have to demo that plaster and start over, because a little cyanuric acid on the surface of the plaster would be the least of your problems.

So, based on these shocking results, this company - that coincidentally makes cal hypo products and owns a few non-chlorine alternative sanitizer labels - decided to do a 6 month tank test. Now they introduce water chemistry parameters. I know that because the say so, a conversation conspicuously absent from the 5 week test. They say the “water in the test tank was adjusted to try and maintain pH between 7.2 and 7.8 and alkalinity between 60 to 100 ppm”. The key phrase there is “try and maintain”. Note that it doesn’t say, like it does later when talking about the 4 month test in test pools “were maintained at…” Old “try and maintain” indicates that boat was missed. So we can assume, from the very language of the report, that, because they were using new plaster coupons, they weren’t able to maintain their own stated water chemistry parameters. You know how it is; three day weekends, somebody forgot, etc.

Too, repeat those water chemistry parameters back to yourself; 7.2 to 7.8 pH and 60 to 100 ppm alkalinity. What happened to 7.4 to 7.6 and 80 to 120? That’s industry standard, isn’t it? Then, after stating these parameters, they contradict them in the next to the last paragraph, where they admit “that pH and alkalinity of the tanks ran on the high side (pH~8, TA~90 ppm), but then they say that despite “the high pH and alkalinity in the test tank, plaster degradation was still seen.

Really? Look at the 3 photos, labeled 100 ppm, 250 ppm & 500 ppm. Those are the ones from the test tanks. Looks like scaling to me, which is exactly what you get when you run your pool water scaling on the Saturation Index.

Now, these “dramatic results” prompted them to do yet a third study; “additional tests were initiated in larger bodies of water where the water balance could be maintained more easily”. They operated five test pools, maintaining their water chemistry at 7.2 to 7.6 pH, alkalinity at 80 to 120 ppm and calcium hardness at 180 to 250.

After four months, they took pictures, which you can see at the bottom of their page. On the left, you have 14X magnified plaster coupon immersed for 4 months in 0 ppm cyanuric acid. Look hard at that photo. Doesn’t that surface look like the beginning of an etched surface? Doesn’t that look like we’ve already burned off the butter and we’re starting to expose the aggregate?

Now look at the plaster coupon on the right, the one that was in the pool with 200-250 ppm cyanuric acid. That’s looks severely etched, doesn’t it? Well, 7.2 pH, 80 ppm alkalinity and 180 ppm calcium hardness is an aggressive environment, all the way up to 80 degrees, assuming a minimum TDS of 430 (their calcium hardness and their cyanuric acid), and all the way up to 90 degrees if the TDS was a little higher, even as little as 80 points higher.

But let’s say that this was done in an air conditioned laboratory in Georgia. A reasonable assumption, right? So, let’s assume a water temperature of 72 degrees. That water is even more corrosive. An extra 0.1, and it being a logarithmic number, 0.1 is a doubling of it’s corrosiveness. Basically, that water is 5 times more corrosive than water balanced to the industry standard of 7.5 pH, 100 ppm TA, 200 minimum Calcium Hardness and average water temp of 78 degrees.

I’m using the handy automated Langelier Index provided by one of the folks who host this study on the internet. You can find it here:

http://www.tricitypool.com/tc-satindex.html

Now, I have a couple of questions about this report.

1. Why did they use such low calcium levels? 180 to 250 isn’t mean calcium as recommended in our industry. When we all start up pools, we make sure the calcium is at least 200 ppm, and I’ve always been told by plaster consultants whose opinions I have come to respect that probably 250 ppm is a better place to start, that 200 ppm is the minimum. And the reason we start our calcium so low is to let the level grow over time, with condensation and the addition of calcium based chlorine products. But why run it so low in the lab? Why not set and hold all pools at 250 or 300 ppm? Because the lower calcium sure clouds the conclusion that it was cyanuric acid, and not out of balance water, that caused the etching.

2. Why is the loss of cyanuric acid only mentioned in the first 5 week study? Did the application of water chemistry parameters in the 2 subsequent tests eliminate that phenomena? Shouldn’t we be able to see the buildup that they talked about in the first test in the 5 photos from the second and third test that accompany this article? Shouldn’t there have been some mention of how they were constantly reintroducing cyanuric acid to the test tanks and test pool in the 6 month and 4 month studies? Remember that quote from Dr. Meyer in a Pool & Spa News article: “The cyanuric acid was no longer in solution… It was on the plaster surface, having some kind of affect.”

Obviously, she’s referring to the first 5 week test. But that quote is mixed in, where the previous paragraph is talking about the 6 and 4 month tests, making it sound like every time you get high stabilizer levels you end up with cyanuric acid falling out of solution. If that were the case, we really wouldn’t have to worry about high stabilizer, would we? Every time it hit 200, we’d just wait a few weeks for it to drop back to 100 and then vacuum the residue to waste.

3. Why in the world would they use freshly troweled plaster coupons to run this test? When would new, uncured plaster ever be exposed to cyanuric acid levels as high as 500 ppm? Not only is it not Real World, it’s not even Real Lab. After all, shouldn’t the lab make an effort to replicate the conditions you’re going to face in your customer’s backyards. Like I said, unless you bring a 50 lbs. bucket of cyanuric acid poolside and dissolve most of it in on Day One of startup, you’re never going to see the conditions they talk about in this report. And by the time you do, you’re going to have two or three year old, very well cured plaster. Of course, there will be folks who will want to play What If on this point. All I can say is that What If is a game for children and not one we ought to be playing in the laboratories and in the professional journals of our industry.

So, why do I care about the Arch Study? Because it is having an affect on our industries perception of cyanuric acid. Look at all the places I’ve found where it’s referenced as the report that shines the light on plaster damage caused by cyanuric acid:

http://www.tricitypool.com/tc-plaster_study.html

http://piscines-apollo.com/docs/arch_plaster_study.pdf

http://findarticles.com/p/articles/mi_m0NTB/is_23_44/ai_n15932555

http://www.encyclopedia.com/doc/1G1-139716069.html

http://www.highbeam.com/doc/1G1-139716069.html

http://www.bookrags.com/highbeam/plaster-problem-arch-study-tackles-hb/

http://www.allbusiness.com/arts-entertainment-recreation/875089-1.html

http://www.tricitypool.com/tc-plaster_cyanuric_study.html

http://www.poolspanews.com/2008/052/052acid.html

That took five minutes of googling to come up with those links. And it doesn’t even scratch the surface of all the times this study is linked to in the forums - or the Finger Pulling Contest, as I like to call them - and probably 50 or 100 times throughout the thousands of forum threads discussing pools and plaster problems.

But now, whenever people google for the Arch Plaster Study, a link to this blog piece will come up as well.

What irritates me the most is how easily we were all duped. Honestly, why didn’t everyone say to themselves, “200 ppm stabilizer in the water may be high, but if I wait 5 weeks half of it is not going to fall out of solution, UNLESS I jack around with the water chemistry so much that EVERYTHING is going to fall out of solution.”

And that was the first chart on the page. We’ve all sat here and looked at that for all these years, and none of us, me included, has stopped to say, “Hey, wait a minute. That never happens.”

Is it just politeness that causes us to not ask those basic questions? I mean, when knowledgeable people have interviewed Dr. Meyer over the years, didn’t it come up? Something like, “Gosh, Dr. Meyer, you’re the first person in the history of history to report a 50 to 70% loss of cyanuric acid over a 5 week period. Are you sure you were watching that pH and not, intentionally or unintentionally, creating an environment where that was the only logical outcome?”

The Elephant in the Room, as it were.

Or is it because this report supports what a lot of people want to believe about cyanuric acid, and so it becomes the Straw Man for that camp? If you’re face is reddening as you read this, then maybe there’s some truth to that.

The craziest thing about all this is, I’ve heard there are people trying to DUPLICATE THE RESULTS OF THIS TEST and consider their tests failures when they don’t achieve the same results. You see, this thing has become the standard that other efforts are gauged by. It is now assumed that cyanuric acid damages plaster and it’s just a matter of holding your tongue right to achieve the same “proof” that Dr. Meyer achieved.

All I know is this thing gets referenced all the time, usually as “recent studies indicate that large quantities of cyanuric acid can even damage plaster”.

I’ve said it before and I’ll say it again: Lions and Tigers and Bears, oh my!

This study is being used by different groups of people to different ends. The folks at Arch are using it to generate heat for cya based products and a bump for sales of their calcium based chlorine and another reason for people to consider their alternative sanitizers, like Baquacil. People have argued with me that I’m wrong there because Arch also sells cya based products, too. Well, how is encouraging people to keep their cya level between 25 and 50 ppm anything but good for trichlor sales?

That tricity link is on the website of a company that’s big on UV sanitizing. There’s nothing wrong with that. UV sanitizing works and it’s not a scam to be selling the units. And throwing rocks at high cyanuric acid won’t hurt those sales, either.

This report supports a philosophy, a philosophy that high cyanuric acid is bad for us. And it is. The more I read and research, the more convinced I become that high levels of cyanuric acid are inhibiting our ability to effectively combat the growing threat of cryptosporidium outbreaks. Too, from what I've read, it does have the general effect, in high levels, of reducing the kill time of chlorine.

But it doesn’t destroy plaster. Not in the Real World. If a guy lets his pool get to 200 or 300 or 500 ppm cyanuric acid, he’s got enough other bad water chemistry habits to destroy the plaster without cyanuric acid having anything to do with it.

Now, I tried to play fair on this. I e-mailed Dr. Meyer on February 28th and asked her, “when you raised cyanuric acid to 250 and 500 ppm, did you use any correction factor on your observed TA?”

On March, 13th, she wrote back that, “yes, we did use a correction factor on our observed TA for the pool study that was run. We subtracted 1/3 of our CYA reading from the observed total alkalinity to get the carbonate alkalinity.”

I wrote again on March 14th to ask her about the issues of the cyanuric acid falling out of solution, and asked why they used new plaster vice cured plaster coupons for their tests.

She has not responded. If she does, and if she can explain any of this, then I’ll gladly amend what I’ve posted here.

Instead of arguing about whether you can create test tank or test pool environments that will damage plaster, how about somebody asking a useful question, like, "why, when I buy that Chinese cyanuric acid in bulk from my supplier do I end up using twice as much as I used to?"

I'm working on it. I'll have an answer in a couple of months. Sooner, I hope. Also, there’s a second, more “in-depth” brochure about the effects of high cyanuric acid that Arch has produced. I’ll be reviewing it in the next few weeks. So stay tuned.

Monday, May 12, 2008

You Can Get More With A Gun & A Smile Than With A Smile Alone

I’ve noticed that many of the links on this blog are dead. I’ll be going through the archives and trying to update them this next month or so.

The one that surprised me most - sort of - was that Bio Guard removed all of their Material Safety Data Sheets from their website. They didn’t just move them so that my links would be dead. They completely removed them and put a note, “To request MSDS for BioGuard products, please contact our BioGuard Customer Care by phone at 1.800.932.5943”.

Just a few months ago their entire library was available at their website. Now, they want to control who they release that information to. Why?

Perhaps it’s because they prefer that the public thinks their “essential minerals” in their Mineral Springs program are a “proprietary blend of minerals” instead of common salt and borax. Yes, the same Borax that Ronald Reagan used to shill for on Death Valley Days. I guess if you’re selling common salt and a laundry additive for something like $40.00 a 30 lbs. bag, you need to control who you release that information to.

You can achieve much the same results of a bag of Mineral Springs Beginnings with about $5.00 worth of salt (a forty lbs. bag at the Big Box store), a 4 lbs. box of sodium tetraborate decahydrate (20 Mule Team Borax) that sells for $2.99, and a little over a quart of muriatic acid to neutralize the borax.

If you use the median percentages for a bag of Renew it’s 2.4 lbs salt, about 7 ozs. of 20 Mule Team Borax, and 4 ozs. of liquid muriatic acid. That’s between $1.50 and $2.00, depending on where you shop. How much are you paying for Renew?

Here’s excerpts from an e-mail from a lady whose had quite enough of the whole Mineral Springs program:

“I stumbled across your blog as I was hunting for cheaper prices for Mineral Springs-Renewal that we have to put in our pool every week. I started reading all the articles and although I thought I was a fairly-informed consumer.

I can see I was totally wrong when it comes to these systems. So my question is--what now? Our pool was put in by [Big Pool Company], (Atlanta, Georgia area) in August 2007. We have had no troubles except now--trying to keep the PH low and the cyanuric acid up and the price of the Renewal--it is totally stupid--up to 26-30 dollars per week--no, I did not sign up for this! We take a pool water sample to our local [Big Pool Company] store in Loganville, GA and they test it for free--we never leave there without needing 90-150 dollars of chemicals.....

Our pool is still under warranty and after reading your articles and all the links--I want our of this system--any suggestions???? Any advise would be appreciated.”

$26 to $30 a week for $2.00 worth of salt and laundry powder... Think I’m making it up? Look again at the MSDS for Renew and do the calculations yourself. The “Inorganic salt” is salt. The Boron Salt is a product very similar to 20 Mule Team Borax. The Inorganic Acid is a granular acid to balance the pH from the high pH Boron salt (I substituted an equivalent amount of liquid muriatic acid in my calculations), and the Aluminum salt is just in there as a desiccant, to keep things dry. When you add it all up and replace with off-the -shelf bulk items, it comes out to about $2.00 for 4 lbs.

I’ve talked about all this before. Click on the Label Getting Screwed Buying Salt. It’s all there. And the BioGuard links have been Renewed, for a lot less than $30 a week.

Sunday, August 19, 2007

Who You Gonna Call?



Last week I talked about the pool store hustle of dressing Baking Soda up with a smidgen of something else, or by calling it a less familiar name, then selling it as Total Alkalinity (TA) Control so that they could charge usurious prices for it. It was really just a lead-in so I could point out that while charging three or four times the supermarket price for Baking Soda is one thing, the idea of selling plain old salt and a little borate and acids and charging as much as ten times more than the going price is just obscene.

Evan, a frequent contributor to the comments section here at The Pool Biz, wrote to say, “Yes, I have to agree that everything you said is true”. Evan works in a pool store.

The Chem Geek, another frequent contributor to the blog, wrote to say, “If your point is that the pool and spa industry is not fully disclosing and that there are myths and falsehoods spread and that the training is poor, I think that's a given. If you look up the antonym of integrity, you'll probably find this industry.” [emphasis mine… wasn’t that a great line?]

But they both also pointed out, in their own ways, that not everyone in the industry is a Big Fat Liar.

Chem Geek said it directly; “That doesn’t mean, however, that everything an industry person says is wrong.”

Evan took a more circuitous route, by pointing out that everything I said in that blog piece was Been There, Talked About That kinda stuff in his beloved forums, and then launched into a rant about high cyanuric acid (CYA) levels and how the pool chemical manufacturers, particularly Chemtura, are lying about how destructive high CYA levels can be to plaster. And, too, if you have read some of Evan the Waterbear’s posts you’ll see that he’s one of the Good Guy. He’s looked behind the curtain and I believe that he sees the same thing I do; that there’s a bunch of salesmen flipping the levers and spinning the wheels on nearly everything in this industry, and that a technical person with the Correct Answer doesn’t hardly have a chance.

Now, that’s a lot of words to be putting in his mouth, so I encourage you to check back and click on the Comments Section Monday night. I’m sure I’ll have a rebuttal from him by then.

The most pointed and direct rebuttal I got was from a man who runs a large pool construction, service and sales company. His business includes a pool store. Via e-mail he said, “On the TA with higher pH, that is actually required around here (and in many other places) where tablets are the primary sanitizer. In those pools (probably 80% in this part of the world), the tablets constantly cause the TA to decrease and likewise the pH. The boosting with a higher pH TA solves two issues with one dose. As for the price of balancing chemicals: There are clearly some that charge usury fees for common items, but I believe it a little jaded to condemn a reasonable profit in the face of the services provided by our ‘boutique’. When a customer comes in, we greet them (usually by name), talk to them, test their water, help them select just the right product, help them to their car with their stuff, and basically establish a relationship. Those are not things you can find at Loews or Home Depot. Many places sell chemicals to get the water right. The only problem is that they don't have your smarts to select them. In those cases (and it happens all day everyday) the customer comes in from Wal-Mart, Home Depot, Loews, or wherever, and ask us to ‘help them’ get their pool ‘fixed’.”

After reading what he said, I had to admit that he was right. There is a purpose for a Pool Store beyond just being a place for pool cleaners to load up their chemicals and for pool repairmen to drink their morning coffee before heading out on their service calls. What he’s saying is the guys on staff at the pool companies who meet and greet the do-it-yourself customers actually have a purpose in life, and as long as they’re well trained and not driven by the owner to Sell, Sell, Sell, then they can be an asset to the pool owner with the Green Pool who’s out there, wandering from Mass Marketer to Franchise Pool Store to Independent Pool Store seeking the Truth.

Truth is, until I read this guy’s e-mail, I never really had much use for the Retail Guys. First off, they always look so neat and clean. I hate that. And when you listen to them with a customer, they always seem to be talking so knowledgeably about pools without ever having seen anything more than the display model in the back of the store. We called them Shop Pussies in my day. I mean, they didn’t even have a decent tan. How can you take advice from a Pool Guy who doesn’t at least have a good Farmer’s Tan working?

But I get his point that listening to a Shop Pussy who’s at least read the water chemistry books is better than navigating the aisles at the Mass Marketers and asking a Homer to point you in the general direction of the pool supplies. You really do have to know what you’re buying when you go to the Mass Marketers. Let me give you a real life example.

I walked into a backyard this past spring. The owners are in that segment of the pool market who only remember they have a 20,000 gallon pool in their backyard in the spring when the kids start asking, “When can we go swimming?” As usual, they were in desperate need of getting someone to come in and get rid of the algae and debris that a winter’s worth of neglect had allowed to accumulate. I looked over their pool and one of the first things I noticed was a very light copper green patina on the plaster and especially on the soft white rubber tires of their automatic pool cleaner. I turned and asked them, “Do you buy your chlorine tablets at Home Depot?”

The answer was yes.


I’ve seen that same staining on half a dozen do-it-yourselfer’s pools, and every time I nose around the equipment area or garage, I find a bucket of HTH Pace Dual Action 3” stabilized chlorine tablets. HTH Pace is owned by Arch Chemicals. The Dual Action tabs are 93.5% Trichloro-s-triazenetrione, 1.5% Copper Sulfate Pentahydrate and 5.0% Inert Ingredients.

They work really well. Trichlor is a great sanitizer and oxidizer, and everybody in the pool business knows that copper is a terrific sanitizer and algaecide. There are tons of copper based algaecides on the market, and most ionizers work by introducing copper ions into the water.

And too, high enough levels of copper in your pool water will cause staining, like I see in the pools of those people who just go to the Mass Marketer and buy the same bucket of tabs over and over again, without giving a lot of thought to what all their putting into their pool. I mean, every time they dissolve 100 pounds of these tablets into their pool, they’re also dissolving 1.5 pounds of copper into the water.

A few years ago, when I first saw that Home Depot was selling chlorine tablets with 1.5% Copper Sulfate, I knew that this was going to happen.

Now, the folks at Arch Chemicals are the same folks who are leading the charge about high stabilizer being bad for your pool. They’ve released a study showing degradation of plaster coupons when exposed to higher and higher levels of CYA. And so they’ve got this pool care program whose bedrock is that overstabilization is bad for your pool, that not only is it bad for your plaster, but that high levels affect your sanitizer’s ability to act as a sanitizer. There’s a lot of talk in the forums about this, too. Here are some links from the HTH consumer website about overstabilization.

http://www.archchemicals.com/Fed/HTH/Poolcare/overstabalization.htm

http://www.archchemicals.com/Fed/HTH/Docs/Overstabilization_Layout.pdf

That first link says it all. It sort of denudes their intentions: “HTH® and calcium hypochlorite (cal hypo) offer the only complete solution to overstabilization. Cal hypo products do not contain cyanuric acid and will not cause overstabilization.”

You see, for most folks who’ve been around this industry a long time, HTH Pace has always been synonymous with calcium based products. I remember going to a Raypak heater training seminar in southern California back about 1984 or 85 and the Raypak Rep holding up a section of 1 ½ inch copper pipe – there was still a lot of it out there back then – that was so scaled with calcium that you couldn’t get a pencil down the middle of it. He asked, “What causes this, fellas?” and we answered back in unison, “Cal Hypo”, because back in those days they used to sell this neat little gadget that you loaded up with those HTH cal hypo pellets and then you put it in the skimmer basket to let erosion dissolve the pellets at the rate determined by the dial-a-setting opening in the lid.

Of course, if you’re in a part of the country with hard water, then a daily diet of calcium for your pool is bad juju. You’re adding more calcium to water that’s already near the tipping point for calcium to start with. Sort of like throwing gas on a fire. The result is always the same; calcium scaling. I’ve seen pools in southern California that were so scaled with calcium that they had to be sanded after they were acid washed. Now, that’s not all HTH’s fault. Once calcium gets much over four or five hundred parts per million (ppm), it gets harder and harder to keep the calcium in solution.

And if you’re in a part of the country with really soft water, so soft out of the tap that you have to actually add calcium to get it up to 200 ppm, then that dial-a-lid thingie would be just fine… sort of.

Because you really need to consider that the pH of calcium hypochlorite is 11.8 and so it’s going to create a higher pH, calcium rich water stream from the skimmer through the equipment. Does that calcium rich, high pH water cause any of the calcium to fall out of solution and plate out on the interiors on your pumps and filters and heaters and plumbing?

Confusing, huh? If you’re in the business, then even as sketchy as it was, you followed everything I just said. If you’re not in the business, then you probably already closed this window.

Now the point I’m trying to make is to those of you still reading, those of you in the business. We are all of us manipulated by people in our industry who are manipulating the facts, and the best manipulator that we run into ends up getting us in their camp. Our own local water conditions come into play somewhat, but I believe that more than water, its The Argument that they present. But, when you look behind the curtain, it turns out that The Argument is 90% Sales Pitch.

Is Arch doing anything wrong by saying that high stabilizer is bad? Probably not. But I know it helps to sell a product that I dismissed a long time ago as inappropriate for day to day chlorination of my customer’s pools.

Is Chemtura doing something wrong by sticking with the story that there’s nothing wrong with stabilizer levels as high as 200 ppm? I don’t know. But it sure helps them sell a lot more trichlor tabs.

Is there reason to question research done on trichlor tabs by a company who tells you it’s a good idea to put calcium based chlorine tablets in your skimmer? You tell me.

Is there a problem with a company putting 1.5% copper into trichlor tabs and then telling people to shock their pool every week with an 11.8 pH oxidizer and never once bring up the issue of copper staining, and on top of that, sell this product in an environment – a Big Box store – where thorough water testing is impossible?

Now, I’m not picking on Arch. That’s the whole point. I could just as easily have taken the other side of the argument and made them look like Heroes. These are the kinds of holes that you and I know exist in every one of these guy’s arguments, in every article we read, in every opinion we see put forth. Everybody’s selling something, and doing and saying what they need to say to get it sold. If they can get you talking about the other guy’s shortcomings, then theirs will slip right under the radar.

The damnable thing to me is that we have to keep learning this crap over and over and over again.


It goes back to what the Chem Geek said; “That doesn't mean, however, that everything an industry person says is wrong. It just means you need to trust, but verify". And I think that’s the same thing the man was saying about his Pool Store when he talked about helping “them select just the right product”.

But who do you believe? Who do you trust? Even if you go to the internet and find a link and click it open and read a report that confirms your suspicions, only to find that the report was commissioned by the competition…

Good luck with all that.