And now this heater comes with a cupro-nickel upgrade. Your pool professional may not even know about it yet. It's not yet stocked at the wholesale distributors. It's the Catch-22 of distribution; in order for them to regularly stock something, they have to have a history of orders for it. But for you to get something they don't normally stock you have to pay freight from the manufacturer. Add the extra cost of the cupro-nickel heat exchanger and you are probably talking several hundred dollars more. But it's worth every penny.
The Sta Rite Max E Therm & Pentair Master Temp heaters are the best, most reliable heaters on the market. Hands down. And now, with the cupro-nickel heat exchanger upgrade, they earn the first ever Pool Guy Seal of Approval.
Anybody who reads this blog regularly knows that I've never said many nice things about any pool equipment manufacturer's stuff, so this really is a big deal.
I love this heater. And with cupro-nickel, I recommend it.
EDIT 5/15/10: Since I wrote this, yet another Master Temp has failed on one of my salt pools. First the thermostat failed, then the heat exchanger. All within the first year. They had a salt system that required 3,000 ppm. So, then, I took a hard look at everything we were doing on this pool to see what it could be that was contributing to the problem. The local Pentair guy told my heater repairman that he had seen that a lot of companies were running chlorine tabs in the skimmers during the winter and he thought it was probably this. But I take the tablets away from my guys in the winter. It's a real easy way for me to get the stabilizer level down to normal on my tab pools. The guys don't have tabs to use anywhere, so the result is that by spring, after the rains, I have pretty normal stabilizer levels going into summer. During the winter we just add a little cal hypo each week. Our water here is soft (120 ppm calcium from the tap on average), so the extra calcium is usually not an issue.
The reason the Rep thought that guys might be using tabs in the winter is that, when the pool water gets down to 50 or 55 degrees, the systems stop making chlorine. You see, they measure the conductivity of the water to determine the salinity level of the pool, and when the water gets cold, it changes that value enough that at 55 and below, the conductivity measurement is so far out of bed that it can't be used. And the water's so cold that the pool hardly needs chlorine anyway, so it's not a bad thing that it shuts off. But since it does, it requires that small amounts of any other chlorine product be used to keep the chlorine level up. I guess some guys out there drop a tab in the skimmer. But we don't, for the reason I stated.
Then, I got a call from a friend of mine asking me to talk with another pool service company owner here in Dallas about a Master Temp that he's put several heat exchangers on, the last one the cupro nickel that I was so high on last year. The cupro nickel lasted two years. All of the copper ones before that (four in all) lasted a year or less - just like what I saw. I talked to the pool company owner for awhile and we kicked around the idea that the only thing we didn't know in these situations and the only part of all of this that was really out of our control was stray current corrosion.
It reminded me of something I'd read online at an APSP forum, a post by Rod Ogilve:
"...I have an interesting story. First let me tell you a little back ground, we have a water table average of 4' to 5' deep. Virtually every pool has well points. OK, this problem started 9 or so months ago. A customer called to tell me their salt pool has a problem with stray voltage. Whenever they touch the hand rail, they get a little shock. I did not build the pool, but I know the electrician and know the bonding was done correctly. I first checked the obvious to no avail. Eventually, I took up the deck and found the bonding wire to be OK. I installed a copper mat under the deck to increase the grid. This did not help. I had the power company come out and tested everything. They could not find a problem. We drained the pool to get rid of the salt, and the problem was reduced 90% but not perfect. The owners gave up and decided that is life. I have always ran this through my head as to why we could not find the cause. Two weeks ago I drove by just to check, and while I was there, a man drove up and asked if I knew anything about submersible well pumps. I asked him where he lived, and he was about 1/2 mile away. I went over to his house and pulled the pump out of the well casing and noticed the wires at the pump were exposed to the water. I told him to call and get another pump and have it installed. The pool customer called the next day to ask how I fixed the problem on the pool. Would you believe the stray voltage was traveling 1/2 mile and manifesting itself at the pool. I found out today the power company had a faulty ground on a pole, so the voltage was going the pool because it was the best ground in the area due to the faulty power company ground. Well, the pool now is full of salt again, and the customer is happy (at least for now :) "
Rod Ogilve is a very well respected pool builder. He's APSP CPB (Association of Pool & Spa Professionals Certified Pool Builder) and so, as far as pool experts go, he's about as good as it gets.
Here's a link to the whole thread. It's mostly pool builders like Rod who have posted to it. The majority consensus is that salt sucks. There are some great horror show photos of salt damage to stone and slate that rival anything I ever posted in this blog. You ought to take a look:
So, getting back to the Master Temp heaters. I still like the Master Temp for any application but salt. I no longer have a recommendation for a heater with a salt system. I strongly believe that there are too many other variables - like the bonding grid throughout a neighborhood and the opportunity for stray currents to be amplified by the more conductive salt water - that you can't control.
Another Flash Bulletin: All of Hayward's heaters now have a Cupro Nickel heat exchanger. You can no longer buy a Hayward heater with a copper heat exchanger. But still, if you ask any Big 3 Rep if salt has an adverse effect on heat exchangers, they will tell you no. And if you come to a Rep with a heat exchanger problem due to salt, he'll tell you he doesn't have this problem with any other installer, it's all your fault, something you're doing or something your guys are doing, like putting tabs in the skimmers.
And the most incredible thing to me is that they do all of this with a straight face. They tell us there's no problem with salt WHILE THEY UPGRADE THEIR HEATERS TO A MORE SALT RESISTANT METAL.
Okay, fine... Back to the blog post:
A new heat exchanger installed is over $1,000.00, and I’ve been noticing a lot of people that got to this blog by Googling for “damaged heat exchanger salt pool”, or variations on that theme. So, it is a worthy investment.
And here’s the Smoking Gun I was talking about. In December, 2006, Hayward had a brochure on their H400 heaters that read: “Cupro nickel is a supremely resilient material that provides product durability and longevity. Cupro nickel aligns well with today’s popular salt -based systems and offers outstanding corrosion resistance".
Yet their warranty as of today is that “higher than normal dissolved solids (pH above 7.8)” will void your one year limited warranty.
These are all things that, once again, dovetail nicely into protecting shareholder value. But over time, as all major corporations are learning the shortcomings of shareholder values as a strategy, it has adversely affected the reputation of their products and the patience of their customers.
Here are some of the real tragedies that have arisen out of Heaters with Salt:
The Jandy LT & LX heaters have a dry well for the high limit switches. The way it works is that these brass dry wells are set into the plastic inlet/outlet header and the high limit switches are pressed against that brass surface. That way, as the water rushes through the header, it’s heat will be transferred to these switches via the brass dry well. That keeps the high limit switch dry so that it won’t become corroded while still allowing it to accurately sense the water temperature. This is how we avoid a runaway heater. If the temperature of the water gets up to 135 degrees, then the first switch will turn off the heater. And if that part fails, then the second high limit will turn it off when it reaches 150 degrees. It’s a great system and all heaters have similar safety devices.
If you look in the Jandy LX/LT Owner’s Manual, you won’t find any mention of the brass wells. On the parts diagram, they show an exploded view of the inlet/outlet header, and they picture the high limit switch assembly. But no brass wells. So, why is all this important?
Because if you put this heater on a pool with a salt system, especially the salt system that Zodiac makes because it uses 4,000 ppm salt, which is even more corrosive than the 3,500 ppm that most of the others use, my experience is that within a year or two, you’ll have your first high limit failure. The threads of the brass well fail and allow water, salty water, to enter into the dry well and corrode the high limit switches. Not a big deal, right? Just replace the high limits and you’re back in business. Problem is, the next time it happens is sooner than the last time. And the next time is sooner than that, etc. You see, the corrosion on the threads gets worse and worse.
So, what’s a mother to do? Well, if you talk to Jandy, at first they tell you to replace the header. But when you price it out and figure that with labor you’re looking at somewhere near $1,000.00 for the job, you call them back and tell them that you’ll recommend your customer buy a different heater before you do that. Then they tell you about this little kit they have, called the LX/LT Sensor Stud Assembly Replacement Kit, Part Number R0383200. It’s carded for easy display. How funny is that? A part that’s not even detailed in the Owner’s Manual, but they had enough call for it that they carded it for wall display.
You order the kit and go take the heater apart, and I mean take it completely apart to get to this thing, and you put the new brass dry well in and you replace the corroded high limits, too, and you’re done for around $350 to $450, depending on how fast you work and what your labor rates are.
Then, in a year or two you get to do it again.
That’s why I strongly recommend against installing a Jandy LT or LX heater anywhere you have a salt system installed.
Now, people will say, “Hey, Pool Guy. Where do you get off badmouthing a perfectly good heater because someone told you they saw something happen on a pool somewhere?”
Allow me to retort: I have 16 pools on service with LT heaters. 13 of them have salt systems and the other three have tablet feeders. I got all those pools on service when they were brand new. Since I put them on service, 11 of the salt pools have had high limit failures, most of them numerous times. None of the pools with tablet feeders have had high limit failures. Fortunately, most of the failures occurred during the three year extended warranty that comes with a new pool when all the equipment is from a single manufacturer. But now they’re all out of warranty and the homeowners are facing these annual repair bills, with no end in sight. Their options are about $150 to $185 per occurrence for high limit switch failures, $350 to $450 per occurrence for dry well & high limit switch replacement, or about $1,000 for inlet/outlet header replacement, or about $3,000 to buy a new heater that doesn’t have this problem.
Now, I’m just a pool cleaner. And my ethic has always been to never sell anything to a customer that isn’t going to work out for them, and if I inadvertently do, go back and clean up my mess. Because just as Jack Welch and Jim Cramer and all the guys at Bear Stearns and AIG et al are finally starting to understand, your main constituencies are your customers and your products.
You see, these are the things that irritated me the most about the Salt Revolution; how cavalierly they threw salt water at pool heaters. It was good for quarterly profitability and for Hitting the Numbers. But, it turns out, not good for much else.