Monday, August 20, 2012

Call Me Crazy: Zinc Balls & High Current Flow

I took most of the summer off this year. It was great. Not only did I get away from the Texas heat, but I spent most of the summer in a city that has very few swimming pools - San Francisco. It was great. Foggy and cool, or sunny and cool, or windy and cool. It was cool.

Then I came home. It was over 100 degrees every day for about the first ten days I was back. Got me all tuned up and back in-the-mode again.

Two things caught my eye after a summer of not thinking much about anything but walking up and down hills and not sweating. The first is this pic I snagged at my local pool wholesale supplier:


Notice the little black sign? SALTWATER PROBLEMS? Sacrificial Zinc Anode. They put stuff behind the counter for easy access to their higher volume articles. They have a whole warehouse of merchandise for sale, and about one hundred square feet of display space behind the counter, and right in the center of that display area are sacrificial zinc balls.

I wrote about zinc balls WAY BACK HERE. It was one of the first pieces I wrote, back when everyone was saying, "the Poolguy's  crazy, but you might want to put some Zinc Balls in your skimmer baskets, anyway".

If you look at that photo again, let your eyes wander down from that sign to counter top level, and then over to your left, and you'll see another item for sale on a blue card, it's another variety of sacrificial zinc anode. This one is meant to be installed in the plumbing line so that it has direct contact to the pool's bonding grid. In fact, if you go to POOLTOOL.COM, you'll see that Saltwater Problems have turned into big business for this company. Clearly, their top-selling items are Salt Pool related.

That's really the Smoking Gun, you know, attaching to the bonding grid. That's the same as an admission that Stray Currents are amplified and made much more destructive by these Salt Systems. That's why they want you to attach a sacrificial zinc anode to that grid; to put the least noble (softest) metal out there to bear the brunt of damage from the Stray Currents riding on your pool's bonding grid. The truth is your non-salt pool may have Stray Currents on the bonding gird as well, but you don't have highly conductive salt water to amplify the damaging effects.

Too, there's a chance that the units themselves could introduce Stray Currents onto your pool's bonding grid. No one's really done any testing to see.

Anecdotally, there's the recent article in Pool & Spa News that a salt system manufacturer is suing a pool equipment distributor for breech of contract; not paying for salt systems they received and resold for installation in people's back yard. You know, like YOUR back yard. The distributor explained that the reason they didn't pay was that the systems were faulty, in that they MELTED DURING OPERATION.

Hmmm... don't you hate that when your salt system melts down? It's better than having them EXPLODE, but only a little bit better. One of the installing company was quoted in the article as saying, "They are melting... It's a huge safety issue... I'm afraid someone's going to get hurt. It's a public safety hazard".

Turns out the first installing activity quoted in the article has installed "more than 200" of these systems in people's back yards, and now they're worried that the systems WILL MELT. The article doesn't indicate whether this company has notified these customers about the potential hazards in their back yard.

I'm betting not.

Another company had installed about 40 units, and when failures - READ MELTED SALT CELLS - topped 25% of installed systems, they yanked them all out of their customer's back yards and discontinued sales of the units. So, they're the Good Guys in the story.

Use the link above to the P&SN article and you can see a picture of one of the char-broiled salt cells. If you recognize it as something like what you have in your back yard, RUN!

You see, with most Salt Systems, you're running something less than 20 amps, but not much less. I know 20 amps because the cell fuse for a Goldline AquaRite is a 20 amp fuse. Leave a little + or - room, and you've got somewhere around 15 to 18 amps going through that cell on an average day. If I remember my old safety courses from the Navy, it takes 100 milliamps (one tenth of one amp) to kill you, so this is about 150 to 180 times the current requirements to kill someone. So it's easy to see how it would melt the salt cell. The company who makes this stuff admits that the salt cells melt, but blames it on the installers, saying they didn't properly connect the brass pins to the salt cell, allowing them to overheat and cause melting of the plastic salt cell housing.

The reason they heat up is because with a faulty connection, you have more resistance to current flow. The argument for the safety of putting 20 amps into the water is that with very little resistance between the cell plates, you never have any Stray Current leaking out via other, higher resistance paths to ground. But as you increase resistance to the current flow through a faulty connection, and you have a power supply capable of putting out 20 amps max, you basically have a recipe for disaster.

My blog is full of incidents of pool owners feeling a "tingling" when they grab a ladder or a side rail at their pool. That's Stray Currents, amigos.

I still marvel that we're having a discussion about the advisability of putting a known corrosive (salt) into pool water and then whacking in with something near 20 amps of current flow to save a buck on chlorine tabs.

Call me crazy...


Wednesday, June 06, 2012

Shameless Self Promotion

I know you all came here for help with your salt swimming pool, and there's plenty of that info here. But this post is about MY NEW NOVEL. Yes, you heard it here first. VAMPIRES IN PARADISE: A TALE OF LOVE, BLOOD & ADDICTION is available HERE & on AMAZON, or if you're over the "hold the book in my hands" thing, you can get the E-book for a mere 99 cents HERE. If you buy the trade paperback at Amazon, you can combine it with any other purchase and get free shipping.



Try it. You'll like it... And then tell your friends.

Then, scroll on down this page for blog posts relative to your problems with your salt pool.

Monday, February 20, 2012

Proof That Builder Not Playing With Full Deck Emerges







Yep. You guessed it. The Pool Guy Rides Again. Hi Ho, Silver, and all that...

Reason I just can't keep quiet is on full display in these two photos. Take a look and tell me, "what's wrong with these photos"?








Yes. That's a Coates Electric Heater.















And yes, that's an Intellichlor Salt Cell plumbed into the outlet of that Coates Electric Heater.














Still see nothing wrong with this? Okay. Let's try doing a little light reading (you're gonna have to click on the Limited Warranty to make it big enough to read. Here's a little hint; skip down to item 4 on the Coates Heater Limited Warranty):




Isn't that funny? A builder intentionally built a spa and used a Coates stainless steel electric heater with a Intellichlor salt system big enough for at least a 15,000 gallon pool, which automatically voided the warranty on the Coates electric heater.

Why would he do that, you may ask. Especially when he's building that spa for a guy who can afford all of this:





























Truth is, he built a reflecting pool on the other terrace of this guy's penthouse. Built it in the same style as the spa, with the big glass walls and - yep, you guessed it - a salt system. He sold him another Intellichlor salt system for a six inch deep basin of water that no one even wades in. And guess what material he used for the corners to join the glass panels on both the spa and the reflecting pool?
























That's right. Once again, our Intrepid Builder used stainless steel. Because if it's good enough for the electric heater folks, it's good enough... Hey, wait a minute. Something's not right here. It's NOT good enough for the heater folks. In fact, they denied the warranty claim on the failed and leaking heat exchanger the minute they saw that salt cell plumbed in line. And maybe that's why the reflecting pool lost watertight integrity at one of those stainless steel corners and leaked out and down and through the deck and then through the ceiling of the penthouse below. And of course there was an automatic water leveler on the reflecting pool so no one put two and two together for awhile on where the water was coming from.

Imagine that phone call...

Ring... Ring... "Hello.. Yeah, this is (owner of penthouse upstairs from the flooding penthouse). Who's this? Maintenance? Yeah, what can I do for you? No. I'm not leaking any water up here. I'm good to go. No, my reflecting pool's just fine... What's that? How do I know it's fine? Because the water level is the same as it always is, that's how I know it's just fine."


Now, anyone who's read very many of my blog posts knows that I'm somewhat less than forgiving when so-called Pool & Spa Professionals make bone-head mistakes like this. I figure if you're gonna advertise your services as Pro Builder, then Buy the Ticket, Take the Ride. And in this case, if this was all that was wrong, I'd say it's just a moron who knows squat about equipment, material and salt compatibility, even though every trade journal and even some manufacturers have been saying for years that you need to READ THE FU&%$G DIRECTIONS, especially the Limited Warranties - hence the term LIMITED warranty - before you spec a project that's going to include salt.

But this guy holds a special place in my heart, because in addition to all of these money grubbing, bone headed moves, he sold two - count 'em; two - complete Intellitouch control systems: One for the spa (okay, I'll buy that) and one for the reflecting pool...

Yes, that's right. One for the reflecting pool. The one that doesn't do anything but... well, reflect.

And so it goes....